Promotional Starter Kit Electrocardiograph ECG a .. . .

P131-1-7909
      
Stock Call for availability

Promotional Starter Kit Electrocardiograph ECG and Orbit Spiro Combo Includes: Smart ECG™, Orbit Portable Spirometer, 100 Mouthpieces, Office Medic Software
Sold by: EA OF 1

 Reviews
Better together

  • Total: $0.00
addthis

VECTRACOR UNIVERSAL ECG™ & ORBIT SPIROMETER Item Description: Universal SmartECG & Spiro Promo, Includes: Universal SmartECG, Orbit™ Spirometer, Box of 100 Mouthpieces and Office Medic Software Supplier Item Code: 790009-00Key Features Includes the QRS Smart ECG, Orbit Spiro, 100 mouthpieces, and Office Medic Software Utilizes Louvaine algorithm for best accuracy Powered via USB connection, doesn't require any batteries Office Medic Software stores and prints diagnostics for records Condition: Factory New Warranty: 1 Year Description The QRS Universal SmartECG and Spiro Package (#790009-00) includes the Universal SmartECG (#Z-7000-0500), Orbit Portable Spirometer (#Z-7000-0101), a box of 100 mouthpieces, and the Office Medic Software. Warranty: 1 Year - Free from Defects in Material and Workmanship. When it comes with diagnosing heart disease, it's vital that caregivers have access to accurate ECG testing. The Universal ECG can help diagnose and monitor patients with cardiovascular issues so caregivers can better treat them. The device maintains accuracy by using the Louvaine algorithm, which had the most accuracy when compared to nine other algorithms by cardiologists. This ECG device is also battery-free, as it draws power from the attached PC via USB port. The Office Medic Software is easy to use and intuitive. It allows caregivers to store diagnostic data for review, and create printouts in PDF, JPEG, and TIFF formats compatible with EMR. Specifications QRS Universal SmartECG and Spiro Package Specifications Universal SmartECG Specifications Hub Weight: 250 - 335 grams. Hub Dimensions: 85 mm x 91 mm x 20 mm. Patient Leads Length: Limb: 1 meter. Chest: 0.6 meter. PC Connection Length: 1.8 meters (USB Type A connector). Case Material: ABS Plastic. Electrode Connection: 4 mm Banana plug with "snap" or "tab" connectors. Gain Sensitivity: 5, 10, 20 mm/mV. Speed: 12.5, 25, and 50 mm/s. Input Range: ± 6 mV. Acquisition Sample Rate: 1000 samples/sec. Heart Rate Range: 20 - 170 bpm. Frequency Response: 0.05 - 175 Hz ± 3dB. Defibrillation Protection: Patient leads are isolated from system and operator, with 4kV protection. Common Mode Rejection: - 60 dB (minimum). Safety Standards: Complies with AAMI EC11, EN60601-1, EN60601-2, EN60601-2-25. Leads Off Indicators: Connection status for each lead is shown on Acquisition screen. Power Source: PC, powered from USB interface. Supply Voltage: 4 - 16 V DC. Supply Current: Less than 17 mA DC. Permanent Filters: High Pass: 0.05 Hz 1st order; Low Pass: 170 Hz 1st order. Baseline Wander: Baseline reset by adaptive zeroing algorithm. Notch Filter (Mains Noise Rejection): 50 Hz 4th order Butterworth, 49.1 Hz - 50.9 Hz. 60 Hz 4th order Butterworth, 59.1 Hz - 60.9 Hz Low Pass (Muscle Artifact Filter): 35 Hz 4th Order. Report Capabilities: User Selectable Report Formats - (1) 3 x 4 Simultaneous; (2) 3 x 4 Sequential; (3) 6 x 2 ECG; (4) 6 x 1 ECG; (5) Averaged Complexes ECG; (6) ECG Measurements Report; (7) Avg. Zoom Report; (8) Zoom Report. Interpretation: Rhythm, Morphology. Environmental Conditions: Operating Temperature: 0 to 40 °C. Storage Conditions: -20 to 70 °C. Humidity: 85% Max. (non-condensing). Orbit Spirometer Specifications Weight: 0.5 lb (226.8 grams). Dimensions: 4.3" x 3.7" x 1.7" (109.2 mm x 94 mm x 43.2 mm). Communication Port: USB (2.0 or higher). Software Compatibility: Office Medic Version 5.5 (or later). Environmental Conditions: Ambient Temperature: -15 to 50 °C. Relative Humidity: 90% Maximum (non-condensing). Atmospheric Pressure: 700 to 1060 hPa. Power Supply: Internal: 5 Vdc, ± 5% 100 mA or less from the host PC USB Port. Measurement Method: FLOW: Mouthpiece (US Patent #4,905,709). Range (BTPS): FLOW: ± 14 liters/second. VOLUME: 0.5 - 8 liters. Accuracy (BTPS): FLOW: FEF25-75: ± 5% of indication or ± 200 ml/sec, whichever is greater; PEF: ± 10% of indication or ± 300 ml/sec, whichever is greater. VOLUME: FVC and FEV1: ± 3% of indication or ± 50 ml, whichever is greater; MVV: ± 10% of indication or ± 15 L/min, whichever is greater. Precision (BTPS): FLOW: PEF: ± 5% of indication or 150 ml/sec, whichever is greater. VOLUME: FVC and FEV1: ± 3% of indication or 50 ml, whichever is greater. Calibration: ATS 3-speed or standard calibration check. Measuring Time: FVC: 60 seconds. SVC: 60 seconds. MVV: 15 seconds. Sampling Rate: 125 Hz. Safety: IEC/EN 60601-1. IEC/EN 60601-1-2. Printed Scale: Flow Volume: (vertical) 5 mm/L/S, (horizontal) 10 mm/L. Volume Time: (vertical) 10 mm/L, (horizontal) 10 mm/S. Parameters Measured: FVC, FEV0.5, FEV1, FEV6, FEV1/FEV6, FEV3, FEV1/FVC, FEV3/FVC, PEFR, PEFT, FEF25%, FEF50%, FEF75%, FEF25-75%, FIVC, FIV0.5, FIV1, FIV3, FIV1/FIVC, FIV3/FIVC, PIFR, FIF50%, FIF25-75%, FIF.2-1.2, FVC/FIVC, Extrapolated Volume (Ext. Vol.), EOTV, FET, MVV, RR, MTV, SVC. Languages Available: English, Spanish, French, German, Japanese, Italian, Portuguese.
More Information
No recommended products at the moment.