Welch Allyn 39500 Series OAE Hearing Screener (1/EA)
Welch Allyn OAE Hearing Screener with Charging Stand, Thermal Printer, Bluetooth Wireless and USB Connectivity, Single Use Ear Tip Starter Kit, 3 mm to 15 mm sizes (#39420), Calibration Certificate, and Data Manager Software; 100- 240 V, 50- 60 Hz AC, Lithium-Ion Integrated Battery, IEC Plug Type -B, -C, -G, and -I
Features
- Use this infant hearing screener to rapidly screen newborns and infants with minimal cooperation required
- No behavioral response required for those too young to respond
- Noise-management technology addresses poor test results due to ambient sound
- View, archive and export patient data with Welch Allyn Data Manager Software
- In-the-ear calibration helps improve test accuracy, ensuring probe is secure
- AutoStart check makes sure test is started in acceptable conditions
- User-friendly screen prompts guide staff through the test
- Tests at key speech frequencies—2, 3, 4 and 5 kHz
Note: For use by or on the order of a licensed medical professional.
For the State of California:
Warning: This product can expose you to chemicals known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.
Warning: Item is considered HAZMAT and cannot ship via Air or to AK, GU, HI, PR, VI.
Rally # | 52-4-3940 |
Manufacturer # | 39500 |
GTIN | 00732094237962 |
Brand | Welch Allyn |
Manufacturer | Baxter / Hillrom / Welch Allyn |
Country of Origin | Unknown |
Application | Hearing Screener |
Power Source | AC Power / Battery Operated |
UNSPSC Code | 42182409 |
Warranty | One Year Warranty |
Probe Description | Integrated microphone and receivers in probe head Calibration data stored on probe |
Measurement Type | Distortion product otoacoustic emissions (DPOAE) Transient evoked otoacoustic emissions (TEOAE) |
Frequency Range | DPOAE |
Stimulus Intensity | DPOAE: 50 to 65 dB SPL TEOAE: 80 dB SPL peak equivalent (±3 dB) |
Microphone System Noise | -20 dB SPL @ 2 kHz (1 Hz bandwidth) -13 dB SPL @ 1 kHz (1 Hz bandwidth) |
Dimensions and weight | Length: 40 in. (1.0 meter) Weight: 1.00 oz. (28 gm) |
Connector | HDMI |
Ear Tips | Single-use disposable ear tips |
Instrument Dimensions | 7 in. x 2.75 in. x 1.25 in. (17.78 cm x 6.98 cm x 3.17 cm) |
Instrument Weight | 6.4 oz. (180 gm) |
Display | Color OLED display to provide user information and progress of measurement |
User Input | 4-button keypad to control instrument functions |
Connectors | • Micro-USB for charging and communication • HDMI for probe |
Communication to PC | Micro-USB or Wireless |
Weight | 6.4 oz (180 g) |
Battery | 3.6 V rechargeable lithium ion |
Battery Life | 15 hours on time |
Charge Time | 4 hours to 100% |
Model No. | UES12LCP-050160SPA |
Output | 5.0V DC, 1.6A |
Input | 100-240V AC, 50-60Hz, 500 mA |
Operation | Provides PC database communication and charging |
Test Memory | 250 tests on unit |
Patient Names | Patient names on unit (optional) |
Database Software | Report output to PDF, RTF, Image files |
Operating Temperature | 59°F to 95°F (15°C to 35°C) |
Operating Relative Humidity | 30% to 90% (non-condensing) |
Maximum Operating Altitude | 6000 feet (2000 meters) |
Transport and Storage Temperature | 41°F to 104°F (5°C to 40°C) |
Wireless specification | Transmit Power: Class 2, +3dBm Range: 30 meters line-of-sight Frequency: 2.402 to 2.480 GHz |
Coexistence | IEEE 802.11 (Implementation) |
Antenna | Internal, chip antenna: Max. gain 0.5 dBi |
Operating Temperature | -40 °C to +85 °C |
Operating voltage | 2.7V to 3.6V |
General Specifications
Type | Thermal Dot Matrix |
Print mode | Thermal line dot print |
Communication | Wireless |
Printing width | 48mm |
Resolution | 8 dots/mm (203dpi) |
Dots per line | 384 dots |
Thermal paper width | 56mm +/- 1mm, max 40mm diameter |
Printer mechanism life | 10^8 print pulses or 50km paper |
Interface options | USB (Mini-USB) RS-232 (6-pin mini-DIN) Infrared (RAW_IR, VIR, IrDA) Wireless Class2 (up to 10m range) – serial port profile (SPP) |
Battery pack | 2-cell Li-Ion battery pack 7.4V-1500mAh, 100-240 V, 50/60 Hz |
Power supply / charger | 39407 |
Maximum current consumption | 0.5A |
Dimensions | 102x75x45mm (WxLxH) |
Weight | 205g including battery, without paper |
Operational temperature range | -10C to 50C (14F to 122F) |
Operational humidity range | 20% to 85% |
Storage temperature range | -20C to 70C (-4F to 158F) |
Wireless
Wireless specification | Transmit Power: Class 2, +3dBm Range: 30 meters line-of-sight Frequency: 2.402 to 2.480 GHz |
Coexistence | IEEE 802.11 (Implementation) |
Antenna | Internal, chip antenna: Max. gain 1 dBi |
Operating Temperature | -20 °C to +70 °C |
Operating voltage | 3.3V |
Computer Requirements (minimum)
• CPU: 1 GHz
• RAM: 512 MB
• Hard Disk: 2 GB
• CD-ROM: Required if installing from a CD
• Network connections: 1 each if installing from a network location or printing to a network printer
• Internet browser: Internet Explorer 6.0 or later and current service pack are recommended
• USB Port: 1 each for the screener, data manager and, if used, a printer
• Display Resolution: 1024 x 768
Supported Operating Systems
• Microsoft Windows 7 Pro, 8.1 Pro and 10
Software Requirements
• Microsoft .NET Framework version 4.0 (bundled with installer if not already installed)
• AdobeReader
• FTDI USB Driver for instrument connection
Configurations
39500 | OAE Hearing Screener Complete System (includes printer, disposable ear tip starter kit and charging cradle) |
39500-NP | OAE Hearing Screener Complete System (printer not included, disposable ear tip starter kit and charging cradle) |
Optional Services
S1-395 | 1 Year Comprehensive Partnership Service Agreement |
S1-395-C | 1 Year Comprehensive Partnership Service Agreement with Annual Preventive Maintenance/Calibration |
S1-395-2 | 2 Year Comprehensive Partnership Service Agreement |
S1-395-2C | 2 Year Comprehensive Partnership Service Agreement with Annual Preventive Maintenance/Calibration |
Accessories
39402 | OAE Hearing Screener Probe Accessory |
39405 | OAE Hearing Screener Power Supply Accessory |
39407 | Power Supply for MPT-II Thermal Printer; IEC Plug Styles US, EU, UK, AU |
39410 | OAE Hearing Screener MPT-II Thermal Mini Printer |
39412 | OAE Hearing Screener MPT-II Thermal Mini Printer Paper Roll |
39413 | OAE Hearing Screener Charging Cradle |
39414 | USB Communications Cable; USB-A to USB-B |
39415 | Carrying Case; Soft |
39420 | Single Use Ear Tip Starter Kit; Qty. 10 each: 7 mm to 15 mm, 3-5 mm and 5-8 mm Flanged, Qty. 30; Probe Tubes, Qty. 140 |
39421 | Probe Tubes, Pack of 100 |
Single Use Ear Tips
39422-07-025 | Single Use Ear Tips; 7 mm; Qty. 25 |
39422-07-100 | Single Use Ear Tips; 7 mm; Qty. 100 |
39422-08-025 | Single Use Ear Tips; 8 mm; Qty. 25 |
39422-08-100 | Single Use Ear Tips; 8 mm; Qty. 100 |
39422-09-025 | Single Use Ear Tips; 9 mm; Qty. 25 |
39422-09-100 | Single Use Ear Tips; 9 mm; Qty. 100 |
39422-10-025 | Single Use Ear Tips; 10 mm; Qty. 25 |
39422-10-100 | Single Use Ear Tips; 10 mm; Qty. 100 |
39422-11-025 | Single Use Ear Tips; 11 mm; Qty. 25 |
39422-11-100 | Single Use Ear Tips; 11 mm; Qty. 100 |
39422-12-025 | Single Use Ear Tips; 12 mm; Qty. 25 |
39422-12-100 | Single Use Ear Tips; 12 mm; Qty. 100 |
39422-13-025 | Single Use Ear Tips; 13 mm; Qty. 25 |
39422-13-100 | Single Use Ear Tips; 13 mm; Qty. 100 |
39422-14-025 | Single Use Ear Tips; 14 mm; Qty. 25 |
39422-14-100 | Single Use Ear Tips; 14 mm; Qty. 100 |
39422-15-025 | Single Use Ear Tips; 15 mm; Qty. 25 |
39422-15-100 | Single Use Ear Tips; 15 mm; Qty. 100 |
39422-35-025 | Single Use Ear Tip; 3-5 mm Flanged; Qty. 25 |
39422-35-100 | Single Use Ear Tip; 3-5 mm Flanged; Qty. 100 |
39422-47-025 | Single Use Ear Tip; 4-7 mm Flanged; Qty. 25 |
39422-47-100 | Single Use Ear Tip; 4-7 mm Flanged; Qty. 100 |
39422-58-025 | Single Use Ear Tip; 5-8 mm Flanged; Qty. 25 |
39422-58-100 | Single Use Ear Tip; 5-8 mm Flanged; Qty. 100 |
Documentation Links
- Welch Allyn 39500 Series OAE Hearing Screener Brochure
- Welch Allyn 39500 OAE Hearing Screener, Quick Reference Guide
- Welch Allyn 39500 Series OAE Hearing Screener Specification Sheet
- Welch Allyn OAE Hearing Screener, User Manual
- Welch Allyn OAE Data Manager, User Manual
- Instructions for use - MPT-II Mobile Thermal Mini Printer