Monitor Vital Signs Diagnostic SunTech® 247™ Ba .. . .

44-4-0061
      
Stock Short Qty

Monitor Vital Signs Diagnostic SunTech® 247™ Battery Mobile System, BP, Temperature & SpO2 Nellcor®-comp.
Sold by: EA OF 1

 Reviews
Better together

  • Total: $0.00
addthis

SunTech® 247™ Systems & Modules Battery Mobile System, BP, Temperature & SpO2 Nellcor®-comp. 99-0061-00 echnical Specifications SPECIFICATIONS VALUES Patient population Adult and pediatric patients (age 3 and above). Method of measurement Oscillometric Initial inflation pressure 160mmHg +/- 20mmHg Blood Pressure Range: Systolic: 60 – 270mmHg Diastolic: 30 – 170mmHg Blood pressure accuracy Measurements determined with this device are equivalent to those obtained by a trained observer using the cuff/stethoscope auscultation method, within the limits prescribed by the American National Standard, Electronic or automated sphygmomanometers. Blood pressure determination time 35-40 seconds typical for Adult cuff Heart rate range 30-200 bpm +/- 2% or +/- 3 bpm, whichever is greater Temperature range 86°F (30.0°C) – 109.4°F (43.0°C) Temperature accuracy +/- 0.2°F (+/-0.1°C) Functional oxygen saturation range 40-100% Functional oxygen saturation accuracy 70-100% +/- 2 digits (Note: because pulse oximeter equipment measurements are statistically distributed, only about two-thirds of pulse oximeter equipment measurements can be expected to fall within ± 2 digits of the value measured by a CO-oximeter.) Operating conditions 10°C (50°F) to 40°C (104°F) Less than 90% RH Storage conditions -20°C (-4°F) to 55°C (131°F) Less than 90% RH Power External power supply, p/n 19-0013-00 or equivalent approved by SunTech. Input: 100-240V AC @ 47-63 Hz. Output: 6V DC @ 15W. External power supply, p/n 19-0016-00 or equivalent approved by SunTech. Input: 100-240V AC @ 50-60 Hz. Output: 9V DC@ 18W. Calibration Check once per 2 years for BP and Temperature Safety systems Independent hardware over-pressure circuit and redundant software overpressure algorithm to limit cuff pressure to less than 330 mmHg. Independent hardware timing circuit and redundant software timer algorithm to limit the duration of a blood pressure cycle to less than 180 seconds. Dimensions Length = 5.5 inches, Height = 11.5 inches, Width = 3.8 inches; Length =14.0 cm, Height = 29.2 cm, Width = 9.7 cm Standards UL60601-1, CAN/CSA C22.2 601-1 IEC 60601-1, IEC 60601-1-2 (EMC), IEC 60601-1-4, ISO 9919, AAMI SP10:2002, ASTM E 1112, EN 12470-3 Meets “Non-invasive Sphygmomanometers — General Requirements & Supplementary Requirements for Electro-Mechanical BP Measuring Systems”, EN 1060-1, EN 1060-3 Classification Protection against electric shock: Class II (for non-battery version), Internally Powered Equipment (for battery version); Applied parts: Type BF; Mode of operation: Continuous
More Information
No recommended products at the moment.