Rally #52-4-6570
Baxter / Hillrom / Welch Allyn #CC-RXX-AAXX
Diagnostic Cardiology Suite ECG (1/EA)
Connex Cardio PC based 12-Lead Multi-Channel Resting ECG - software, Connex Cardio AM12 wired acquisition module, AHA 10 wire, 12-lead lead set with banana plugs, CardioSens Ultra II resting tab electrodes (pouch of 100), Clear Choice adapter clips (set of 10).
Features
- Launches ECG and spirometry applications directly from EMR.
- Uses one PC-based ECG system for spirometry and ECG exams.
- ECG analysis software streamlines workflow by capturing and saving ECGs in two clicks.
- VERITAS ECG algorithm limits filtering.
- Wireless Acquisition Module (WAM) captures ECGs wirelessly.
- Reduces repeat ECGs by capturing best 10 seconds of data.
- Complies with ACC, AHA, HRS recommendations for adult/pediatric patient ECGs.
- Uses DICOM and HL7 communication.
- Securely control user logins, assign user roles and access audit trails
CAUTION: Federal law restricts this device to sale by or on the order of a physician.
For the State of California:
Warning: This product can expose you to chemicals known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.
Rally # | 52-4-6570 |
Manufacturer # | CC-RXX-AAXX |
GTIN | 00817655022628 |
Brand | Connex® |
Manufacturer | Baxter / Hillrom / Welch Allyn |
Country of Origin | Unknown |
Application | Software Package |
For Use With | For use with ECG Machine |
UNSPSC Code | 43232610 |
Warranty | Thirteen Month Warranty (Software) |
Instrument Type | 12-lead resting electrocardiograph |
Input Channels | Simultaneous acquisition of all 12 leads |
Standard Leads Acquired | I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6 |
Frequency Response | 0.05 Hz - 300 Hz |
Gain | 2.5, 5, 10, 20 mm/mV |
Filters | AC filter: None, 50 Hz, 60 Hz Low-pass filters: 40 Hz, 150 Hz, 300 Hz |
Digital Sampling Rate | 40,000 samples/sec/channel used for pacemaker spike detection 1,000 samples/sec/channel used for recording and analysis |
Report Formats | Standard or Cabrera; 3+1, 3+3, 6, 6+6, or 12 channel |
Acquisition Device | AM12 Acquisition Module |
Storage Capacity | Unlimited with external archive |
Diagnostic Cardiology Suite Software | 13 Months |
Wireless and Wired Acquisition Modules | 1 Year |
UTK | 1 Year |
Lead Wires | 90 Days |
Clips | 90 Days |
Spirometer Hardware | 1 Year |
Operating Systems | Microsoft Windows 10 Professional and Enterprise (64-bit) Microsoft Windows 11 Professional and Enterprise Note: If installing ELI Link with Diagnostic Cardiology Suite system, requires 64-bit OS to operate both. |
Compatible Viewing Resolutions | 1366×768, 1680×1050, 1920×1080, 1920×1200, 2736×1824 |
Font Scaling | 100% |
Processor | Performance equivalent or better than an Intel Core i3 |
RAM | Minimum 4 GB |
Hard Drive Capacity | Minimum 250 GB (If client: minimum 160 GB) |
Archive | Network or external USB drive |
Software Installation | DVD |
Network | 100 Mbps connection or better |
USB Ports | Requires at least two USB 2.0 ports (WAM/AM12 modules, external USB drive) |
Input Devices | Standard keyboard, mouse, ECG acquisition input device (e.g. WAM, AM12 modules) |
Printing Device | HP M501dn Windows Printer with HPUPD PCL5 driver or equivalent |
Instrument Type | Performance equivalent to an Intel® Xeon® class, quad-core with hyperthreading |
Resolution | 1024 x 768 or better |
RAM | Minimum 4 GB |
Operating System | Microsoft Server 2016, Microsoft Server 2019 |
System Disk | 100 GB for OS and product installation (RAID recommended for data redundancy) |
Data Disks | 550 GB hard drive space available HD controller with 128 MB read/write cache (RAID recommended for data redundancy) |