Baxter/Hillrom/Welch Allyn #28600
Welch Allyn TM 286 AutoTymp Tympanometric System (1/EA)
Welch Allyn TM286 AutoTymp Pure Tone and Tympanometry Screener with Tympanometry Mode, Reflex Mode, and Audiometry Mode; Audiometry Headset (External), Threshold Audiometry Card, Thermal Printer Paper (3 rolls), Ear-Tip Set (#26100); 100-240 V, 50-60 Hz AC, IEC Plug Type-B.
Features
- Fast Detection Of Middle Ear Pathologies
- 226 Hz Tympanograms Offer Summary Information
- Manual And Automated Audiometry
- Lightweight And Portable
- Internal Printer
- Acoustic Reflex Measurements Available In 500, 1000, 2000, 4000 Hz Frequencies
Note:
- The instrument is to be used by trained personnel only.
- The instrument is Rx Only.
Warning: This product can expose you to chemicals known to the State of California to cause cancer. For more information, go to www.P65Warnings.ca.gov.
Rally # | 45-1-2860 |
Manufacturer # | 28600 |
GTIN | 00732094082036 |
Brand | TM 286 Autotymp |
Manufacturer | Baxter / Hillrom / Welch Allyn |
Country of Origin | Unknown |
Application | Tympanometer |
UNSPSC Code | 42182416 |
Dimensions | 12.5" W x 14.5" D x 4.7" H (31.8 cm W x 36.8 cm D x 11.9 cm H) |
Weight | 5 lbs (2.3 kg) - unit and probe |
Operating Temperature | 59° F to 104° F (15° C to 40° C) |
Warm-up Time | 10 minutes for instruments stored at room temperature |
Storage/Shipping | -30° F to 149° F (-34° C to 65° C) |
Ambient Pressure | 98 kPa to 104 kPa |
Humidity | 15% to 95% |
Warranty | One Year Warranty |
Probe Tone | 226 Hz, ±2% |
Sound Pressure Level | 226 Hz: 85.5 dB SPL, ±2.0 dB, measured in a 2.0 cm3 coupler |
Harmonic Distortion | < 3% |
Admittance (Compliance) | Range: 226 Hz: 0.0 to 1.5 cm3 or 0.0 to 3.0 cm3 |
Note:
- The range is automatically selected based upon the amplitude of the compensated tympanogram.
- The maximum uncompensated (ECV + tympanogram peak) admittance (compliance) range is 0 to 5.0 cm3.
- ECV/cavity limits for initiating pressurization is 0.2 to 5.0 cm3. Compliance Accuracy: ±0.1 cm 3 or ±5%, whichever is greater.
Pressure Range | +200 to -400 daPa |
Pressure Accuracy | ±10 daPa or ±15%, whichever is greater |
Rate of Sweep | 600 daPa/sec except near tympanogram peak where sweep rate slows to 200 daPa/sec to provide better definition of peak compliance. |
Direction of Sweep | Positive to negative |
Tympanogram Test Time | Approximately 1 second |
Gradient | Measurement of the tympanogram width taken at 50% of peak compliance. |
Note:
- 1 daPa = 1.02 mm H20
- The pressure sweeps to at least -100 daPa. To save test time, pressure sweep stops when tympanogram returns to baseline after -100 daPa.
- Full pressure sweep for 5 cm3 from sea level to 7000 ft. altitude with no leak.
- High compliance tympanograms (test time) will take somewhat longer.
Frequencies | 500, 1000, 2000, and 4000 Hz for ipsilateral stimulation |
Accuracy | ±3% |
Total Harmonic Distortion | < 5% for outputs less than 110 dB HL and <10% at 110 dB HL |
Rise/Fall Time | 5 to 10 msec |
Transducers | |
Ipsilateral | Probe Assembly |
Output Levels | |
Ipsilateral | 500 and 4000 Hz: 80, 90,100 dB HL 1000 and 2000 Hz: 85, 95, 105 dB HL |
Pressure | Reflex measures are set automatically to pressure at peak compliance with an offset of -20 daPa if peak pressure is negative and +20 daPa if peak pressure is positive. |
Reflex Determination | Compliance change of 0.05 cm3 or greater |
Reflex Test Time | 1 to 12 seconds depending upon the number of ipsilateral test frequencies selected (4 maximum) and intensity required. |
Note:
- Ipsilateral stimuli are time multiplexed with probe tone (93 ms ON, 66 ms OFF).
- Stimuli are presented at lowest level first. If there is no response, the intensity is increased by 10 dB until a response is detected or the maximum dB HL is reached.
Probe: | |
Steady Yellow | Occlusion |
Blinking Green | Ready To Start |
Steady Green | Test In Progress |
Steady Orange | Leak In Pressure |
No Light | Test Is Finished |
Frequencies | 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 8000 Hz |
Accuracy | ±2% |
Total Harmonic Distortion | < 2.5% (125 to 3000 Hz measured acoustically at maximum dB HL; 4000 and 6000 Hz measured electrically) |
Audiometric Headset | Pair External Headset earphones Type 51 cushions (10 ohms impedance) Headband force per ANSI S3.6 and IEC 645 (4.5 ±0.5) |
Insert Earphones | Ear Tone Insert earphones (50 ohm impedance) |
External Headset Earphones | |
Frequency | Intensity |
125 Hz | -10 to 50 dB HL |
500 to 4000 Hz | -10 to 90 dB HL |
6000 Hz | -10 to 85 dB HL |
250 and 8000 Hz | -10 to 70 dB HL |
Accuracy | 125 to 4000 Hz ±3 dB 6000 and 8000 Hz ±5 dB |
Step Size | 5 dB |
Signal-to-Noise Ratio | > 70 dB in 1/3 octave; less than -10 dB HL for levels less than 60 dB HL |
Rise/Fall Time | 20 to 50 msec |
Note: An additional +10 dB is available per frequency via the +10 dB button.
Tone is normally off until the Present bar is depressed | |
Continuous | Tone is steady when present bar is depressed |
Pulsed | Tone is pulsed at 2.5/sec (i.e., 200 msec ON, 200 msec OFF) |
FM (frequency modulated) | Tone is frequency modulated at a rate of 5 Hz, ±5% |
Paper Roll Length | Approximately 80 feet (960") |
Tests/Roll | Approximately 230 tests or 115 people |
Assumption | 2 Tympanograms/Reflex + 1 Audiogram per person |
Speed | Approximately 1 minute to print three screens: Tympanogram Tympanogram + reflex (4) Audiogram |
External Printer | Optional Deskjet color printer recognizing PCL3 or PCL3 GUI; 8-1/2" x 11" or A4 format |
Line Voltage | 100 - 240 VAC (±10%) |
Frequency Range | 47 - 63 Hz |
Power Consumption | 16 watts maximum while printing. Low voltage input for desktop |
Power Supplies | 7 VDC, 5.0 A |
Display | 240 x 64 Graphical, Monochrome LCD |
28600 | TM 286 AutoTymp |
05260-U | TM Carrying Case |
23220 | Audiometry Patient Response Switch |
23221 | Audiometry Single Patch Cord, 2-Conductor |
23222 | Audiometry AudioCups |
26008 | TM Eartips 8 mm (box of 25) |
26011 | TM Eartips 11 mm (box of 25) |
26013 | TM Eartips 13 mm (box of 25) |
26015 | TM Eartips 15 mm (box of 25) |
26016 | TM Eartips 16 mm (box of 25) |
26017 | TM Eartips 17 mm (box of 25) |
26018 | TM Eartips 18 mm (box of 25) |
26019 | TM Eartips 19 mm (box of 25) |
26020 | TM Eartips 20 mm (box of 25) |
26100 | TM Eartips (6 sizes, 2 each, 8, 11, 13, 15, 17, 19 mm) |
26240 | TM Dust Cover |
26241 | TM Test Cavity |
28203 | DD45 Audiometry Headset External |
28206 | Threshold Audiometry Card |
28209 | External Audiometry Headset (Required Calibration) |
28210 | Welch Allyn Y-Cord Headset (Two-Plug Shielded) |
28601 | TM286 Power Brick (for devices with serial numbers GS0077116 and earlier) |
28602 | TM286 Cord, Power, Hosp Grade |
28603 | TM286 Instructions for Use Manual (printed, English only) |
28604 | TM286 Quick Reference Guide |
28607 | TM Wall Chart for Tymp tracings |
52600 | TM Printer Paper, 4” Thermal, 5 rolls |
729243 | Power Supply AM282, TM 286, 4th Edition (for devices with serial numbers GS0077117 and later) |